SYSTXCC4ZC01 Manuals


SYSTXCC4ZC01
Infinity Damper Control
Visit www.carrier.com
Installation and Start-Up Instructions
GER, WARNING, and CAUTION. These words are used with
the safety-alert symbol. DANGER identifies the most serious
hazards, which will result in severe personal injury or death.
WARNING signifies a hazard, which could result in personal
injury or death. CAUTION is used to identify unsafe practices,
which would result in minor personal injury or product and
property damage. NOTE is used to highlight suggestions which
will result in enhanced installation, reliability, or operation.
INSTALLATION CONSIDERATIONS
Before the actual installation of a zoning system can begin,
decisions need to be made to determine the number and location of
zones and sensors. This affects duct and damper selections.
This instruction covers the physical installation and start up of the
Infinity Damper Control. Use this instruction to guide the actual
Infinity Damper Control
installation process after all the air side decisions have been made.
SYSTXCC4ZC01
One Damper Control is capable of handling up to four zones of
A97040
operation. When greater than four zones are required, a second
NOTE: Read the entire instruction manual before starting the
Damper Control Module is needed for zones 5 through 8 (8 zones
installation.
maximum).
This symbol → indicates a change since the last issue.
1. Install the Infinity Zone Control (User Interface) and Remote
Room Sensors in non-condensing areas with ambient tempera-
TABLE OF CONTENTS
tures between 32° F. and 120° F. Install Dampers and Infinity
SAFETY CONSIDERATIONS .....................................................1
Damper Control in non-condensing areas with ambient tem-
INSTALLATION CONSIDERATIONS .......................................1
peratures between -4° F. to 158° F., (-20° to 70° C).
INTRODUCTION ..........................................................................1
2. A TXV is required on the indoor coil when used with all
INSTALLATION ...........................................................................2
residential split system equipment.
Check Equipment and Job Site...........................................2
3. Proper equipment selection and duct sizing are important in a
Component Location and Wiring Considerations ..............2
zoned system.
Install Components ..............................................................3
Install Zone Dampers ..........................................................3
4. DO NOT USE a bypass damper with the Infinity Zoning
Final Wiring.........................................................................4
System. Addition of a bypass will cause improper operation.
Additional Damper Control Board Setup ...........................5
Airflow management will be performed by the User Interface
Optional Transformer Requirements...................................5
algorithms. The User Interface will monitor the system and
System Startup.....................................................................5
will maintain proper airflow through the heating / cooling
equipment.
TROUBLESHOOTING .................................................................7
INTRODUCTION
SAFETY CONSIDERATIONS
The Infinity Zoning System allows air conditioning and heating
Improper installation, adjustment, alteration, service, maintenance,
equipment to control temperatures and humidity in up to 8 distinct
or use can cause fire, electrical shock, or other conditions that may
spaces, or zones, within a building. Each zone has independent
cause personal injury or property damage. Consult a qualified
temperature settings. The comfort temperature settings can change
installer, service agency, or your distributor or branch for infor-
automatically through the use of schedules. This allows the Infinity
mation or assistance. The qualified installer or agency must use
System to change temperature settings in zones to reflect occu-
factory authorized kits or accessories when modifying this product.
pancy or usage. For example, the end user can condition bedrooms
Refer to the individual instructions packaged with the kits or
in a home from 5:00 PM through 7:00 AM or the kitchen from
accessories when installing. Follow all safety codes and wear
3:00 PM through 6:00 PM. The Infinity System uses motorized air
safety glasses. Have fire extinguisher available. Read these in-
volume control dampers (also called zone dampers) to regulate
structions thoroughly and follow all warnings or cautions attached
flow of conditioned air into zones. In this manner, the system can
to the unit. Consult local and state building codes and Sheet Metal
selectively heat or cool certain portions of a building depending
and Air Conditioning National Association (SMACNA) for special
upon space temperature requirements.
installation requirements.
Each zone requires a motorized zone damper to control the air
This is the safety-alert symbol
. When you see this symbol on
supplied to it and a zone sensor to sense temperature in each zone.
the equipment and in the instruction manual, be alert to the
There are three types of zone sensors available and may be used in
potential for personal injury. Understand the signal words DAN-
combination:
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1
4
PC 101
Catalog No. 809-50012
Printed in U.S.A.
Form DAMP4ZC-1SI
Pg 1
04-04
Replaces: NEW