Lytecaster 2004ICV Series Manuals







READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
INSTRUCTION SHEET NO.
This fixture is intended for installation in accordance with the National Electrical Code and local 
or Federal code specifications. To assure full compliance with local codes and regulations, check with your
local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before
IS:2026WH
proceeding.
A0203 Page 1 of 1
Retain these instructions for maintenance reference.
INSTALLATION OF LYTECASTER® REFLECTOR TRIM IN THE 2000LV/2004ICV SERIES 
FRAME-IN KITS WITH ROTO CLIPS
NOTE:
Installation and lamping procedures for the square and round
styles are the same as follows:
1. Frame-In (Fig. A)
See Frame-In Kit Instruction Sheet for installation procedure.
FIG. E
For use with 2000LV/2004ICV series Frame-In Kits only.
2. Rotate Roto Clips (Fig. B)
As shown in Fig. E.
3. Prepare Socket Cup
Remove the Lamp Adjustment Mechanism from the Socket
Cup by bending the the Tabs away (3 places), (see Fig. F & G).
4. Snap-On (Fig. C)
Insert Socket Cup into Housing. Make sure Springs of Socket
Cup 
snap into Slots of Housing Fig. C.
FIG. F
5. Push-in (Fig. D)
FIG. G
Push Housing Trim straight up until it is tight against ceiling.
6. Lamping (Fig. H and I)
Lamp Springs
Lamp
Make sure that power is OFF when lamping or relamping.
Remove Shower Trim from Housing by turning counter-clock-
wise and pulling straight down (Fig. H). Place Lamp into Lamp
Reflector Lip
Spring until face of Lamp sits firmly onto Glass Lamp Guard (Fig.
I). Attach Socket to Lamp. Insert Shower Trim with Lamp back
into Housing by turning clockwise.
FIG. H
FIG. I
CAUTION:
NOTES:
• Lamp manufacturers require the Glass Lamp Guard
• Low voltage fixtures should be dimmed only with
be in place before energizing lamp (with the
special dimmers intended specifically for that pur-
exception of TAL lamps), and that great care must
pose. Use Lightolier Lytemode®, Scenist®,
be taken to insure lamp is fully cooled before
Crescendo VA®, Neptune VA®, Precision VA®,
relamping.
Easyset VA®, Sunrise VA®, Radiant VA®, or equiva-
lent products by others; or variable autotransform-
ers or electronic dimmers intended for use with
low voltage fixtures.

®
LIGHTOLIER a GENLYTE THOMAS company.