Chronotherm IV T8602D Manuals


T8602D Chronotherm® IV
Programmable Thermostats
INSTALLATION INSTRUCTIONS
APPLICATION
The T8602 Chronotherm® IV Programmable Thermostat 
cooling. Refer to Table 1 for a general description of the 
provides electronic control of 24 Vac single-stage heating 
thermostat. All T8602 Thermostats are powered by 
and cooling systems or 750 mV heating and 750 mV 
batteries.
Table 1. Description of T8602 Thermostats.
System
Fan
T8602
System
Changeover
Selection
Selection
Comments
D
Heat-Cool
Manual or 
Heat-Off-Cool or
On-Auto
System and fan selections are done 
Automatic 
Heat-Off-Cool-Auto
by keyboard.
Selectable
Do not install the thermostat where it can be affected by:
MERCURY NOTICE
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
If this control is replacing a control that contains 
— radiant heat from sun or appliances.
mercury in a sealed tube, do not place your old 
— concealed pipes and chimneys.
control in the trash. Dispose of properly.
— unheated (uncooled) areas such as an outside wall 
behind the thermostat.
Contact your local waste management authority 
for instructions regarding recycling and the 
proper disposal of the old control. 
Wallplate Installation
The thermostat can be mounted horizontally on the wall 
or on a 50.8 mm x 101.6 mm (2 in. x 4 in.) wiring box. 
INSTALLATION
Position wallplate horizontally on the wall or on a 
50.8 mm x 101.6 mm (2 in. x 4 in.) wiring box.
When Installing this Product...
1. Position and level the wal plate (for appearance 
only). The thermostat will function properly even 
1. Read these instructions carefully. Failure to follow 
when not level. 
the instructions can damage the product or cause 
2. Use a pencil to mark the mounting holes. See Fig. 
a hazardous condition.
2.
2. Check the ratings given in the instructions and on 
3. Remove the wallplate from the wall and drill two 
the product to make sure the product is suitable for 
4.76 mm (3/16 in.) holes in the wall (if drywall) as 
your application.
marked. For firmer material such as plaster, drill 
3. Installer must be a trained, experienced service 
two 5.56 mm (7/32 in.) holes. Gently tap anchors 
technician.
(provided) into the drilled holes until flush with the 
4. After completing installation, use these instructions 
wall.
to check out the product operation.
4. Position the wallplate over the holes, pulling wires 
through the wiring opening.
Location
5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.
Install the thermostat about 1.5m (5 ft) above the floor in 
an area with good air circulation at average temperature. 
See Fig. 1.
® U.S. Registered Trademark
Copyright © 2003 Honeywell International Inc.  •  
  • All Rights Reserved 
69-1510-4

Document Outline



Big size of image:

Please install Flash player from http://get.adobe.com/flashplayer/!

37 37 48 48

Designated trademarks and brands are the property of their respective owners | Disclaimer