4. Hold the base against the wall. Route the wires through the hole below
TEMPERATURE ADJUSTMENT:
RESETTING AIR FILTER COUNTER
INSTALLATION AND OPERATING
the terminal block. Position the base for best appearance (to hide any marks
Pressing an arrow key once adjusts the set temperature by one degree in
To reset the air filter counter when you replace your filter:
from an old thermostat). Attach the base to the wall with the two screws
the associated direction. Holding the key will automatically advance the
1. Rotate dial to AIR FILTER .
INSTRUCTIONS
provided.
setting in the associated direction.
2. press and release COPY to reset counter
CONNECTING THE WIRES
CHANGING OTHER SETTINGS:
3. Press and release COPY again to restore previous count. 
PSP711CC SERIES
5. Wires must be trapped between black clamp and brass
If there are many choices for a value, usually that setting will automatically
4. Return the dial to the RUN position.
terminal.
advance by holding one of the arrow keys. Some settings though, must be
6. Securely tighten all 7 electrical terminal screws.
changed one press at a time.
SETTING THE AIR FILTER LIFE
This value sets the number of days to be counted before a filter
SMART TEMP® ELECTRONIC THERMOSTAT
DISPLAY ILLUMINATION:
These diagrams are provided for new installations or unreferenced wires.
change is indicated.
Press the light bulb button to illuminate the display. Pressing other
To set the AIR FILTER USAGE LIMIT:
HEATING SYSTEMS
COOLING SYSTEMS
buttons will keep the display illuminated until no button has been pressed for
1. Rotate dial to AIR FILTER.
approximately 20 seconds.
P
M
Easy as
2. LCD shows: SET LIMIT at lower left, with current setting center
JUMPER
JUMPER
FAN MODES:
SET
SUNDAY
PROVIDED
PROVIDED
HEAT
OFF
screen.
WEEKDAY
COOL
PROGRAM
SET
DAY/TIME
1–2–3
The fan switch has three positions AUTO, CLEAN, and ON. Setting the
3. With a new filter installed, use the UP/DOWN keys to change this
G
Y
W RH RC
B
O
G
Y
W RH RC
B
O
FAN switch to AUTO automatically runs your system's fan as required only
value to the number of days of useful filter life specified by your filter
Installs Easily
Set Day and Time
Choose Heat or Cool
for heating and cooling. The CLEAN position insures that your system's fan
manufacturer.
runs at least the programmed minimum duty cycle. The default duty cycle
4. The counter will be reset to zero when usage limit has changed.
LUX PRODUCTS CORPORATION
52027
requires it to run 15 minutes every hour. Setting the FAN switch to ON runs
5. Return the dial to the RUN position.
Mt. Laurel, New Jersey 08054, USA
your system's fan continuously. The FAN icon will flash whenever the fan is
G
W
RH
G
Y
RC
running.
TEMPERATURE OVERRIDE 
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.
RC
R
OVERRIDE allows you to change the current SET TEMPERATURE in
Energizer® is a registered trademark of Eveready Battery Company, Inc.
HEAT or COOL until the next program period without changing your
R
N O T E
DURACELL® is a registered trademark of The Gillette Company, Inc.
The FAN switch works only if your system provides a wire for the
temperature control programs.
F
H
V
F
C*
V
● Press UP/DOWN to change the current temperature setting. The
I M P O R T A N T !
PSP711CC’s “G” terminal.
4
5
6
OVERRIDE indicator appears on display.
Please read all instructions carefully before beginning
SETTING THE TIME AND DAY:
● The OVERRIDE will be canceled at the start of the next program period,
installation. Save them for future reference. Before removing
Open the door on the front of the thermostat. Rotate the dial to the
and the temperature setting will return to its programmed value.
any wiring from your existing thermostat, its wires must be
SET DAY/TIME position. You should see the display pictured below with a
● An OVERRIDE may be terminated by rotating the dial, switching the
HEATING / COOLING SYSTEMS
HEATING / COOLING SYSTEMS
labeled with their terminal designations. Ignore the color of the
day of the week flashing.
mode to OFF, or initiating a HOLD.
4- or 5-WIRE WITH ONE TRANSFORMER
5- or 6-WIRE WITH TWO TRANSFORMERS
wires since they may not comply with any standard.

● Adjusting the set temperature to its program value will also cancel an
Su
Press UP to change day
JUMPER
JUMPER
of week.
OVERRIDE.
Thank you for your confidence in our product. To obtain the best
PROVIDED
REMOVED
● Press NEXT to set the time;
TEMPERATURE HOLD
results from your investment, please read these instructions and acquaint
it will flash.
HOLD may be used for manual temperature control. HOLD is the
yourself with your purchase before installing your new thermostat. Then
G
Y
W RH RC
B
O
G
Y
W RH RC
B
O
12:00
AM
● Press UP or DOWN to
simplest means to set and maintain a fixed temperature. It allows you to
follow the installation procedures, one step at a time. This will save you
change time of day.
set and maintain a fixed temperature indefinitely in Heat or Cool without
time and minimize the chance of damaging the thermostat and the
concern for programming. To initiate a HOLD:
systems it controls. These instructions may contain information beyond
● Press and release HOLD.
that required for your particular installation. Please save for future
When you are finished setting the day and time, rotate the dial to RUN to
reference.
G
Y
W
RH
B*
O
G
Y
W
RH RC
B*
O
return to normal operation or to another position to continue programming.
● Adjust temperature as desired with UP/DOWN.
RC
R
HARDWARE RESET
● Temperature setting will not change until the HOLD is cancelled.
COMPATIBILITY
● To cancel a HOLD, press and release HOLD again, rotate the dial, or
R
This button will unlock your thermostat and read option switch positions,
before the unit begins normal operation. It is located inside on the rear of the
switch mode to OFF.
F
C*
H
V
F
C*
H
V
The PSP711CC can be used with most single stage 24 volt gas, oil or
unit’s circuit board. It is a small square component labeled S8, with a white
6
4
5
6
4
5
electric heating and air conditioning systems, single stage heat pumps, or
button at it’s center.
ADVANCED FEATURES
gas millivolt heating systems. It cannot be used with 3 wire zone valves,
SOFTWARE RESET
120 volt heating systems, or multi stage heat pumps. Ask your dealer for
All COMMON WIRES MUST BE TAPED OFF.
Use this front panel RESET to return all software settings and programs to
TEMPERATURE SWING
other LUXPRO thermostats to control those systems.
their default values. Option jumpers will be read and operation will
If "Y" and "C" are both present, "C" is a common wire. DO NOT USE "C"! TAPE IT OFF!
A thermostat works by turning your heating or cooling system on or off
correspond to their current positions. SOFTWARE RESET is disabled while
FEATURES
whenever the room temperature varies from the set-point temperature.
If a "B" wi
*
re in your system is a system common, then  connecting it at the "B"
your thermostat is locked. To assist in reprogramming, copy your programs
This variation is the "swing." Your system should cycle on about 3 to 6
terminal may cause damage to your system. TAPE IT OFF!
into the chart provided before using SOFTWARE RESET.
times per hour. A smaller swing number increases the number of cycles,
so room temperature is more constant. A larger swing number decreases
2 WIRE SYSTEM HEAT ONLY
the number of cycles, but saves energy in most cases.
UP
PROGRAMMING
SWING SETTING
LARGE
DOWN
BACKLIT
1. Rotate dial to the AIR FILTER position.
LIGHT
G
Y
W
RH
RC
B
O
The PSP711CC provides four independent programming periods per day
DISPLAY
for HEAT, COOL, and FAN. Each is programmed separately. You can use the
2. Simultaneously press NEXT & HOLD.
IAQ 
default programs or alter them to suit your schedule.
3. Use UP/DOWN keys to change swing.
INDEPENDENTLY
JUMPER
4. Choices are 1 through 9. The default is 2.
PROGRAMMABLE
DEFAULT ENERGY STAR® TEMPERATURE PROGRAM
EASY
FAN
As supplied from the factory, the following ENERGY STAR® approved
5. Rotate the dial to the RUN position to finish.
PROGRAMMING
WITH
program will be used for temperature control in RUN mode. This program
TEMPERATURE CALIBRATION
LUX SPEED DIAL®
MODE SWITCH
24 VOLT
and all other software settings may be restored to their default values via a
1. Rotate the dial to SET DAY/TIME.
HEAT
HEAT
SOFTWARE RESET.
TRANSFORMER
2. Simultaneously press NEXT & HOLD.
3. Use UP/DOWN keys to adjust the thermostats calibration by as
120 V CA
PERIOD
HEAT MODE
COOL MODE
much as ± 5°F (± 3°C).
MORN
6:00 AM 70°F (21°C)
6:00 AM 78°F (26°C)
LOCK
3 WIRE SYSTEM HEAT ONLY
MO
(3rd WIRE FOR FAN)
DAY
8:00 AM 62°F (17°C)
8:00 AM 85°F (29°C)
To prevent tampering, press NEXT NEXT
NEXT HOLD. This sequence of keys will lock
NITE
G
Y
W
RH
RC
B
O
EVE
6:00 PM 70°F (21°C)
6:00 PM 78°F (26°C)
HEAT
● Small elegant design
● Temperature Hold
NITE
10:00 PM 62°F (17°C) 10:00 PM 82°F (28°C)
and unlock the set temperature, programs
1:30
● Exclusive LUX Speed Dial®
● Keyboard Lockout
and other settings. When the keys are locked,
70 SET
a padlock icon will be visible above the time
● EL Illuminated Display
● F/C Temperature Display
JUMPER
EDITING HEAT OR COOL PROGRAMS
and temperature display. The Lock will be
FILTER
120
● Comprehensive Graphical
● 12/24 Hr Clock Display
You can change any preset times and/or temperatures to suit your
disabled after a Hardware Reset.
Filter Monitor
● Adjustable Temperature
schedule for each day of the week. The four periods each day are
● 7 Day Programming
Differential / Cycle Rate
Morning(MORN), Day,(DAY) Evening(EVE), and Night(NITE).
24 VOLT
● Energy Star Compliant
● User Temperature Offset /
FAN
HEAT
HEAT
SETUP OPTIONS
● 4 Periods Per Day
Calibration
TRANSFORMER
WEEKDAY PROGRAMMING
PROGRAM MO
● Clean Cycle® (Patent No. 
● 5/2 minute selectable
1. Select HEAT or COOL with the
MORN
120 VAC
JUMPER SETTINGS
6,988,671) Independently 
minimum Run/Off time provides
mode switch.
START AT
HEAT
There are four jumpers, each controls a setting depending on its
Programmable Fan
short cycle and compressor
2. Rotate dial to SET WEEKDAY
3 WIRE SYSTEM COOL ONLY
6:0070 position. 
● Nonvolatile Memory For
protection
PROGRAMS. You will see the display
AM
SET
All Programs And Settings
shown here:
GAS/ELECTRIC MODE - J4
● Temporary Temperature
G
Y
W
RH
RC
B
O
The position of this jumper controls when the thermostat requests the
Override
3. The HEAT or COOL set temperature will be displayed on the right side of
system fan to run. In HEAT mode with the gas jumper in place, the fan is
the display. The start time for the displayed period will flash to show that this
controlled by the heating system itself. In HEAT mode with the jumper
C A U T I O N
JUMPER
may be changed.
open or removed, the fan is controlled by the thermostat. 
4. Use the UP/DOWN arrow keys to change the start time for this period.
5MIN/2MIN MINIMUM RUN TIME - J3
The PSP711CC is protected against normal static electric discharges.
One period ends at the start time of the next period. The beginning of that
To minimize the risk of damaging the unit in extremely dry weather, touch
The position of J3 sets the minimum length of time that the thermostat
period may not be any closer to the beginning of the next period than one
a grounded metal object before touching your thermostat.
24 VOLT
must remain with Heat or Cool either On or Off before it will automatically
A/C
FAN
COOLING
15 minute increment.
COMPRESSOR
switch to the alternate On or Off state. This feature prevents short cycling
TRANSFORMER
5. Press NEXT to accept the displayed start time and advance to edit the
INSTALLATION
and provides compressor protection for cooling units. Choices are 2 or 5
SET TEMPERATURE.
minutes.
120 VAC
6. Use the UP/DOWN arrow keys to change the flashing HEAT or COOL
TEMPERATURE DISPLAY FORMAT °F/C - J2
Please read all instructions carefully before beginning installation.
set temperature to the temperature you desire.
4 WIRE SYSTEM HEATING AND COOLING
The position of this jumper controls whether temperature is displayed
7. Press NEXT to accept the displayed set temperature and advance to
in degrees F° or 
C A U T I O N
edit the start time for the next period. It will be flashing.
TIME DISPLAY FORMAT 12/24 HR CLOCK - J1
Turn off electricity to the appliance before installing or
G
Y
W
RH
RC
B
O
8. Repeat for each of the four periods per day. When all the periods for a
OFF
The position of this jumper controls whether time is displayed in 12
servicing thermostat or any part of the system. Do not
day have been set, the start time for the next morning will be displayed
hour or 24 hour Military Time format.
turn electricity back on until work is completed. 
flashing so that it may be edited.
JUMPER
9. Repeat PROGRAMMING for each remaining day.
REPOSITIONING JUMPERS
● Do not short (jumper) across electric terminals on furnace or air
conditioner to test the system. This may damage the thermostat and
10. Rotate the dial back to RUN to accept all current values and end the
To change a setting, the jumper must be repositioned and a
void your warranty.
programming session.
HARDWARE RESET must be performed. These jumpers are located
inside the thermostat on the rear of its circuit board. To access them,
● All wiring must conform to local codes and ordinances.
24 VOLT
A/C
WEEKEND
FAN
HEAT
HEAT/COOL
remove the unit from the wall by pressing up on the thumb latch at the
● The thermostat should be limited to a maximum of 1.5 amps;
COMPRESSOR
TRANSFORMER
PROGRAMMING
bottom of thermostat and swinging the body out and away.
higher current may cause damage to the thermostat.
1. To program Saturday or Sunday,
PROGRAM
SU
● Your thermostat is a precision instrument. Please handle it with
120 VAC
select HEAT or COOL and rotate the
MORN
The table pictured on the right is also
OPEN
CLOSE
care.
dial to SET WEEKEND PROGRAMS.
START AT
HEAT
printed on the circuit board. The closed or
5 WIRE SYSTEM HEATING AND COOLING
You will see a display similar to that
J4 ELECT
GAS
(2 TRANSFORMER SYSTEM)
6:0070 shorted position is that which covers both a
TOOLS REQUIRED
shown here:
AM
SET
jumpers pins. To prevent its loss, a jumper
J3
2MIN
5MIN
G
Y
W
RH
RC
B
O
2. Use steps 3 - 10 described in
● #1 Phillips screwdriver (small)
may be placed over one pin only for the
J2
C
F
WEEKDAY PROGRAMMING to
● Drill with 3/16-in. (4.8mm) bit
open positions. After settings have been
J1
24HR
12HR
program Saturday and Sunday.
● Wire stripper/cutter
changed, press S8, the HARDWARE RESET
THERMOSTAT LOCATION
button for the changes to take effect. See HARDWARE RESET
COPY BUTTON
JUMPER
COPY will copy the previous day’s Heat, Cool or Fan program into the
On replacement installations, mount the new thermostat in place of the
REMOVED
current day and advance to the beginning of the next day.
old one unless the conditions listed below suggest otherwise. On new
24 VOLT
24 VOLT
BATTERIES AND MAINTENANCE
installations, follow the guidelines listed below.
FAN
COOLING
HEAT
HEAT
COOL
COOL
1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the
TRANSFORMER TRANSFORMER
DAY
PERIOD
HEAT
TIME
TEMP.
TIME
TEMP.
floor, and in a room that is used often.
MORN
INSTALLING BATTERIES/ MAINTENANCE
120 VAC
120 VAC
2. Do not install it where there are unusual heating conditions, such as:
DAY
The PSP711CC requires batteries to operate your heating/cooling
THURS
in direct sunlight; near a lamp, television, radiator, register, or fireplace;
COOL
EVE
system. Replace the batteries when the battery REPLACE indicator
SINGLE STAGE HEAT PUMP SYSTEM
DAY
PERIOD
HEAT
NIGHT
near hot water pipes in a wall; near a stove on the other side of a wall.
TIME
TEMP.
TIME
TEMP.
appears in the display or at least once a year.
MORN
MORN
3. Do not locate in unusual cooling conditions, such as: on a wall
1. Switch electricity to the furnace and air conditioner OFF.
DAY
DAY
separating an unheated room; or in a draft from a stairwell, door, or
G
Y
W
RH
RC
B*
O*
MON
FRI
2. To access your units batteries remove the unit from the wall by
EVE
EVE
window.
pressing up on the thumb latch at the bottom of thermostat and swinging
NIGHT
NIGHT
4. Do not locate in a damp area. This can lead to corrosion that may
MORN
the body up and away.
ADD
JUMPER
MORN
shorten thermostat life.
JUMPER
DAY
DAY
3. Remove the used batteries.
TUES
SAT
EVE
EVE
5. Do not locate where air circulation is poor, such as: in a corner or an
4. Install two new Energizer or DURACELL "AA" size alkaline
NIGHT
NIGHT
batteries in the battery compartment. Observe the polarity marking
alcove; or behind an open door.
MORN
MORN
shown in the compartment.
6. Do not install the unit until all construction work and painting has
24 VOLT
HEAT
CHANGEOVER
CHANGEOVER
DAY
DAY
FAN
WED
SUN
been completed.
HEAT
PUMP
5. Hang the top of the unit by the tabs at the top corners of the base,
TRANSFORMER
HEAT
COOL
EVE
EVE
NIGHT
NIGHT
then snap the bottom of the unit into place. Do not use unnecessary
120 VAC
*"B" OR "O" BUT NEVER BOTH
force. If the body does not snap into place easily, remove the body,
C A U T I O N
CLEAN CYCLE®.
re-hang it from the tabs and try again.
The CLEAN CYCLE feature insures that the fan runs for at least the
● Read instructions carefully before removing any wiring from existing
COMPLETING YOUR INSTALLATION
6. Turn the power back on to your heating and/or air conditioning
7. See Setup Options to configure jumpers.
thermostat.
specified duration each hour to circulate and filter the air in your home.
system. If this is the first time you are installing batteries, the thermostat
Hourly fan run time may be specified from 9 to 60 minutes per hour."60" =

8. Install two new Energizer or DURACELL "AA" size alkaline batteries at
Wires must be labeled before they are removed.
will display "SUN 12:00 AM".
this time. For instructions, see BATTERIES/MAINTENANCE.
ON or continuous run. The default minimum run time is 15 minutes total per
● Do not allow wires to touch each other or parts on thermostat.
Within 90 seconds the thermostat will begin to display the room
9.  Install your PSP711CC on its base.
hour. Additional fan run time is not called for when the heating or cooling
temperature alternately with the time. To correct the display, see "Setting
● When removing wires from their terminals, ignore the color of the
To do this hang the top of the unit by the
requirement exceeds the threshold setting. When additional fan run time is
the TIME and DAY,"
wires since they may not comply with any standard.
after you set the programs.
N O T E
Remove sticker from display.
tabs on the base, then snap the bottom
required, it is met by running the fan at 20 minute intervals, for 1/3 the hourly
of the unit into place. Do not use
run time setting. 
REMOVING THE OLD THERMOSTAT
unnecessary force. If the body does not snap into place easily, remove the
EDITING THE CLEAN CYCLE® PROGRAMS
TECHNICAL ASSISTANCE
1. Turn rotary dial to SET FAN
Y
1. Switch electricity to the furnace and air conditioner
body, re-hang it from the tabs and try again.
W
OFF; then proceed with the following steps.
10. Turn the power back on to your heating and/or air conditioning system.
PROGRAMS. You will see a display
PROGRAM MO
If you have any problems installing or using this thermostat, please
F
2. Remove cover from old thermostat. Most are snap-
AN
MORN
11. Verify that the system and its fan are operating properly. When set to a
similar to that shown here:
carefully and thoroughly review the instruction manual. If you require
S
on types and simply pull off. Some have locking
TART AT
high temperature, the heating system should provide warm air after a short
2. The start time for the displayed
assistance, please contact our Technical Assistance Department at 856-
screws on the side. These must be loosened.
time. Likewise, a cooling system should provide cool air after a short time.
period will flash to show that this may
234-8803 during regular business hours between 8:00AM and 4:30PM
6:00
AM
3. Note the letters printed near the terminals. Attach
Usually sound from the furnace and air conditioning units can be heard while
be changed. Use the UP/DOWN arrow
Eastern Standard Time, Monday through Friday. You can also receive
labels (enclosed) to each wire for identification.
they are running. The rush of moving air should be heard within a short time
keys to change the start time for this
technical assistance online anytime day or night at
Remove and label wires one at a time. Make sure the wires do not fall
after either has been started.
period. One period ends at the start
http://www.luxproproducts.com. Our web site offers you answers to the
back inside the wall.
12. Your installation is now complete.
time of the next period. The beginning of that period may not be any closer
most common technical questions, and also permits you to email your
4. Loosen all screws on the old thermostat and remove it from the wall.
to the beginning of the next period than one 15 minute increment.
questions to our technical support staff at your convenience.
MOUNTING THE PSP711CC
N O T E
3. Press NEXT. The minimum run time flashes to show that it may be
edited.
1. Strip insulation leaving 3/8 in.
If you have an electric system and the blower does not operate after
4. To change the minimum run time for this period, use the UP/DOWN
WARRANTY
Y
Y
installation, find the electric/gas heat jumper on the back of the body.
W
(9.5mm) bare wire ends and clean off
W
Move the jumper to ELEC and perform a HARDWARE RESET.
keys.
R
any corrosion.
Limited Warranty: If this unit fails because of defects in materials or
5. Press NEXT to accept the setting and progress to the next period.
2. Fill wall opening with non-
workmanship within three years of date of original purchase, LUX
combustible insulation to prevent drafts
OPERATING INSTRUCTIONS
6. Repeat for each of the four periods per day.
Products Corporation will, at its option, repair or replace it. This warranty
from affecting the thermostat.
7. When all the periods for a day have been set, the start time for the next
does not cover damage by accident, misuse, or failure to follow
morning will be flashing so that it may be edited.
installation instructions. Implied warranties are limited in duration to three
The PSP711CC alternately displays the current time and the room
8. Repeat programming for each remaining day.
years from date of original purchase. Some states do not allow limitations
temperature. It also displays the day of the week and the current program
9. Rotate the dial back to RUN to accept all current values and end the
on how long an implied warranty lasts, so the above limitation may not
C A U T I O N
period, MORN, DAY, EVE, or NITE. Set temperatures are indicated in the
programming session.
apply to you. Please return malfunctioning or defective units to the
right side of the display.
Be careful not to drop the unit or disturb electronic parts.
participating retailer from which purchase was made, along with proof of
AIR FILTER USAGE MONITOR
Leave the door closed while the body is being removed
You can make program or setting changes with the thermostat body on
purchase. Please refer to "TECHNICAL ASSISTANCE" before returning
from the base.
the wall, or conveniently removed from its base plate.
The AIR FILTER USAGE MONITOR counts the number of days a filter
thermostat. Purchaser assumes all risks and liability for incidental and
SYSTEM MODES:
has been in use. In RUN mode, the display shows the remaining filter life
consequential damage resulting from installation and use of this unit.
via a bar-graph, and the number of DAYS LEFT in the 3 digit filter display
3. Remove the body from the thermostat’s base by pressing the thumb
The Mode switch has three positions HEAT, OFF, and COOL. In the winter,
Some states do not allow the exclusion of incidental or consequential
area.
latch at the bottom center of the unit and swinging the body away.
set the system switch to HEAT to control your heating system. In the
damages, so the above exclusion may not apply to you. This warranty
CHANGE FILTER
summer, set the switch to COOL to control your air conditioner. In spring and
will appear when the days remaining has reached
gives you specific legal rights and you may also have other rights which
fall or when the windows are open, you can set the switch OFF.
zero and the filter should be changed. DAYS OVER is indicated when a
vary from state to state. Applicable in the U.S.A. only.
N O T E
filter change is past due. Setting filter usage to 000 will disable this
If you are mounting the base to soft material like plasterboard or if you
UP/DOWN/CHANGE ARROW KEYS:
function. The filter section of the display will not be highlighted when this
are using the old mounting holes, the screws may not hold. Drill a 3/16
There are two arrow keys just right of the unit’s display. They are used to
function is disabled. The filter counter can count from 000 to 999 days.
in. (4.8mm) hole at each screw, and insert the plastic anchors provided.
adjust set temperatures and change other settings.
The default air filter life is 90 days.
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED


Big size of image:

Please install Flash player from http://get.adobe.com/flashplayer/!

39 39 46 46

Designated trademarks and brands are the property of their respective owners | Disclaimer