Installation
Connect the Battery
Placement / Power
In compliance with Department of Transportation (DOT) regulations, the Back-UPS is shipped with the
Avoid placing the Back-UPS in:
internal red battery wire disconnected. The Back-UPS will not operate until the internal red wire is con-
®
®
nected to the battery. Once connected, allow the Back-UPS to charge for a full eight hours prior to use.
  •
Direct sunlight
Note: Small sparks may occur during battery connection. This is normal.
  •
Excessive heat
  •
Excessive humidity or in contact with fluids
www.apc.com
 
 
of any type
Back-UPS™
CS
350/500
Plug the Back-UPS into a wall outlet, as shown.
a.
Open the battery compartment, as shown.
c.
Connect the red battery wire to the      positive
battery terminal.
User’s Manual
990-2084A 2/02
b .
Pull the battery about half way out, as shown
d.
Push the battery into the battery compartment
  •
The Back-UPS charges the internal battery
and re-install the cover, as shown.
any time it is connected to a wall outlet.
3 Check the Building
Connect Equipment to the Back-UPS
Connect the Phone
Wiring Fault Indicator
Line to Surge Protection
The rear panel of the Back-UPS consists of the
Monitor
Fax
If the red Building Wiring Fault indicator on the
following elements:
The telephone ports provide lightning surge pro-
rear panel of the Back-UPS is lit, one of the
Battery Back Up Outlets (qty. of 3). These
tection for any device connected to the telephone
following conditions exists:
outlets provide battery back-up, surge protection,
line (computer, modem, fax or telephone). The
Computer
and Electro-magnetic Interference (EMI) filtering.
telephone ports are compatible with Home Phone-
   •  Open or high resistance ground
In case of power outage, battery power is
line Networking Alliance (HPNA) and Digital
   •  Hot or neutral polarity reversed
Printer
automatically provided to these outlets. Power
Suscriber Line (DSL) standards, as well as all
External
   •  Overloaded neutral circuit
(utility or battery) is not supplied to these outlets
modem data rates. Connect as shown.
Drive
when the Back-UPS is switched Off. Connect a
A lit indicator means that a potential shock
computer, monitor, and external disk or CD-ROM
Wall Outlet
hazard exists. Improper building wiring should
drive to these outlets.
Scanner
be corrected by a qualified electrician. Do not
Surge Only Outlets (qty. of 3). These outlets are
use the Back-UPS until the condition that caused
always On  (when utility power is available) and
the fault is corrected.
are not controlled by the  On/Off  switch. These
outlets do not provide power during a power
Black Velcro Straps (qty. of 2 - not shown). For
Note: Improper building wiring will not prevent the
outage. Connect a printer, fax machine or scanner
convenience, two velcro traps have been included
Back-UPS from operating, but it will limit its
to these outlets.
and can be used to manage power cords.
protection capability. It may also result in
equipment damage that is not covered by the APC
Modem/Phone/Fax
Equipment Protection Policy.
Switch On the
Connect USB Cable and Install Software (optional)
Back-UPS
Note: The Back-UPS software CD-ROM provides
computer. The installation program will load
Mac OS 9 (9.0.4/9.1 or higher) Users
Note: Allow the Back-UPS to charge for a full eight
data reporting and unattended shutdown of
automatically. Please follow the on-screen
APC PowerChute Personal Edition Software has
computers connected to the device.  The User’s
hours prior to use.
instructions to install the software.
been designed specifically to work with Mac OS 9
Guide contains additional information about the
(9.0.4/9.1 or higher).  There are builds of Mac OS
Press the push-button on the front panel of the
Back-UPS software. The User’s Guide is
 
Windows 2000 Users
prior to Mac OS 9.0.4/9.1 with power drivers that
Back-UPS.
contained in the main folder with the CD-ROM.
The APC PowerChute Personal Edition Software
have known problems, so please make sure that
Attention: USB Hubs
CD-ROM included with your UPS contains a
you have the most up to date version of Mac OS 9
The Back-UPS should be plugged into the USB
“wizard” that optimizes your system’s power
(9.0.4/9.1 or higher).
port of the computer, not into a USB hub.
settings for operation with your Back-UPS. It does
Insert the APC PowerChute Personal Edition
On Line
this by changing various settings in Power
The computer must be powered  On before
Options Properties in the Control Panel. APC
Software CD-ROM into the CD-ROM drive. An
On Battery
connecting the USB cable. Connect the USB cable
strongly advises you to reconfigure your system
icon called “APC Shutdown Manager v1.0.1” will
end (USB symbol facing down) to the rear panel
appear on your desktop. Open the folder and
Overload
by running this wizard.
USB port of the Back-UPS. Connect the other end
double-click the “ReadMe” file. Make sure your
1. Insert the APC PowerChute Personal Edition
Replace Battery
of the USB cable to the USB port (usually located
hardware matches the requirements stated in the
on the rear panel of the computer).
Software CD-ROM into the computer’s CD-
ROM drive.
ReadMe file. Double-click on “APC Shutdown
For other Microsoft®  Windows®  or Macintosh®
Manager v1.0.1” to begin the installation of the
2. Choose “Start” and then the “Run” option.
operating systems, please follow the steps below,
Type: <CD-ROM drive letter>:setup.exe. 
software. At the first dialog, click on “Continue”.
as appropriate:
Click “OK” and follow the instructions.
Read the displayed license agreement and click
“Accept” if you agree to the terms. Click on
 
 
  
Windows 98 and Windows Me Users
Microsoft Windows XP Users
“Install” to begin. After installation, click on the
Observe that the following events occur after
®
“Restart” dialog button to restart your computer.
Please insert the APC PowerChute  Personal
Please visit the APC website at www.apc.com/
pressing and releasing the push-button:
windowsxp for updates on the availability of
Edition Software CD-ROM included with your
All Other Users
Windows XP software.
Back-UPS  into  the  CD-ROM  drive  of  your 
  •
The green On-Line indicator flashes.
The software is designed for the Windows and
Macintosh operating systems mentioned in this
  •
The yellow On Battery indicator lights while
section. If you do not have one of these operating
the Self-Test  is being performed.
systems, your unit will still provide these primary
  •
When  Self-Test has successfully completed,
features:
only the green On Line indicator will be lit.
• Battery backup, surge protection, and telephone 
  •
If the internal battery is not connected, (see
line protection to protect your entire desktop 
TO COMPUTER
Step 1 above) the green On Line indicator and
from lightning and power surges.
USB PORT
red  Replace Battery indicator will light. The
• Runtime needed for you to work through brief 
Back-UPS will also emit a chirping sound.
RJ-45 to USB
power disturbances: provides time to manually 
CABLE
save data and shut down safely. 
Installation of the APC PowerChute Personal
Edition Software is not mandatory. However, other
features provided by the software include
unattended automatic operating system shutdown,
as well as application data saving. To activate
these features, install the software as previously
discussed.
Status Indicators and Alarms
There are four status indicators (lights) on the front
On Battery (yellow) - is lit whenever the bat-
Overload (red) - is lit whenever power demand
Replace Battery (red)  - is lit whenever the bat-
panel of the Back-UPS (On Line, On Battery,
tery of the Back-UPS is powering equipment con-
has exceeded the capacity of the Back-UPS.
tery is near the end of its useful life, or if the bat-
Overload, and Replace Battery).
nected to the Battery Backup Outlets.
tery is not connected (see above). A battery that is
near the end of its useful life has insufficient run-
Four Beeps Every 30 Seconds - this
Continuous Tone - this alarm is
time and should be replaced.
alarm is sounded whenever the Back-
sounded whenever the Battery Backup
UPS is running On Battery. Consider
outlets are overloaded.
Chirps for 1 Minute Every 5 Hours -
On Line
saving work in progress.
this alarm is sounded whenever the
On Battery
battery has failed the automatic diag-
nostic test.
Overload
Circuit Breaker - the circuit breaker
Continuous Beeping - this alarm is
button located on the rear panel of the
Replace Battery
sounded whenever a low battery con-
Back-UPS will stick out if an overload
dition is reached. Battery run-time is
condition forces the Back-UPS to dis-
very low. Promptly save any work in
connect itself from utility power. If the
progress and exit all open applica-
button sticks out, disconnect non-essen-
On Line (green) - is lit whenever utility power
tions. Shutdown the operating system,
tial equipment. Reset the circuit breaker
is powering the Battery Backup outlets.
computer and the Back-UPS.
by pushing the button inward.
APC, PowerChute and Back-UPS are registered trademarks
of American Power Conversion. All other trademarks are
Property of their respective owners.